Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : Fanke High-voltage
Model Number : CHX-108KVA/27KV,108KV
Certification : ISO9001
Place of Origin : China
MOQ : One unit
Price : Negotiable
Payment Terms : T/T
Supply Ability : 10units/1months
Delivery Time : 25-30 Work Days
Packaging Details : Export Standard Wooden Case With Fumigation Free
Test principle : Variable frequency resonant circuit
Test Item : AC withstand voltage test under 108KV
Max.capacity : 108KVA
Max. voltage : 27KV , 54KV, 81KV , 108KV
Design feature : Portable Type , Lighter Single Piece Weight, Special for On-site Installation and test
Component : V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test frequency : 30-300Hz
Duty cycle : 60 mints
Test accuracy : No less than 1.5%
Output waveform : Good sine wave
Test object : 35KV cable , 10KV cable, 35KV power substation
Test standard : IEC 60060-1:2010;IEC 62271-203:2011 for GIS, IEC 60840:2011 for XLPE cable;
Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and Power Substation Test
I. Product Usage :
This test set model CHX-108KVA/27KV, 108KV is designed for 10KV / 35KV class XLPE cable ,power transformer, CB,CT/PT, busbar in 35KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 27KV ,54KV,108KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test
Test range of the set is as following:transformer
1. 500m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 60min.
2, 2000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.
3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.
4, CB,CT/PT, busbar in 35KV power substation , test frequency 40-300Hz, test voltage does not exceed 95kV, test time 1min.
The whole test set consists of variable frequency power source , excitation transformer , 4pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV power sub-station
II. General Technical Data
III. Main Components:
SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension |
1 | Variable frequency power | FKVF-5kW/380V | 1piece | 35kgs | 450*450*500mm |
2 | Excitation transformer | CQSB(J)-5kVA/1.25KV,5KV | 1piece | 35kgs | 450*350*450mm |
3 | HV resonant test reactor | CHX(kf)-27kVA/27kV | 4pieces | 42kgs | D350*H400mm |
4 | Capacitive divider | TRF-110kV/1000pF | 1set | 10kgs | D150*H850mm |
5 | Special test accessories | 1set |
IV. Test priciple :
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
V. Main Measuring and control software panel:
Note: This is the software panel before start test for parameter setting
VI.Accessories
VII. Other Optional Model
1. For GIS on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) |
CHX-135KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS |
CHX-270KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS |
CHX-216KVA/216KV | 27KV*8 | 1A | 216KVA | For 123KV and below GIS |
CHX-270KVA/270KV | 27KV*10 | 1A | 270KVA | For 145KV and below GIS |
CHX-275KVA/275KV | 275KV | 2A | 275KVA | For 170KV and below GIS |
Special requirement can be made by order |
2. For 45KV XLPE cable on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-108/54 | 54KV | 2A | 108KVA | 45kV cable≤1km |
CHX-216/54 | 54KV | 4A | 216KVA | 45kV cable≤2km |
CHX-324/54 | 54KV | 6A | 324KVA | 45kV cable≤3km |
CHX-432/54 | 54KV | 8A | 432KVA | 45kV cable≤4km |
CHX-540/54 | 54KV | 10A | 540KVA | 45kV cable≤5km |
CHX-1080/54 | 54KV | 20A | 1080KVA | 45kV cable≤10km |
Special requirement can be made by order |
3. For 66KV XLPE cable on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-160/80 | 80KV | 2A | 160KVA | 66kV cable≤0.5km |
CHX-320/80 | 80KV | 4A | 320KVA | 66kV cable≤1km |
CHX-640/80 | 80KV | 8A | 640KVA | 66kV cable≤2km |
CHX-960/80 | 80KV | 12A | 960KVA | 66kV cable≤3km |
CHX-1280/80 | 80KV | 16A | 1280KVA | 66kV cable≤4km |
CHX-1600/80 | 80KV | 20A | 1600KVA | 66kV cable≤5km |
CHX-3200/80 | 80KV | 40A | 3200KVA | 66kV cable≤10km |
CHX-9600/80 | 80KV | 120A | 9600KVA | 66kV cable≤20km |
Special requirement can be made by order |
VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable
![]() |
High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test Images |